This is the question that stops an induction hob purchase halfway through, usually at the point someone reads the installation section of the manual and finds the words "must be connected to a dedicated circuit by a qualified electrician".
It's a reasonable question with a genuinely useful answer, and the answer depends almost entirely on what's already behind your existing hob.
The Short Answer
Most full-size four-zone induction hobs draw 6-7.4kW at maximum and need a dedicated cooker circuit — typically 32A radial wiring in 6mm² cable, protected by a 32A breaker, and terminated at a cooker connection unit. That is not a job for a plug socket and it isn't DIY work in England and Wales.
However, a significant and growing number of induction hobs are rated at 2.9-3.5kW and are designed to run from a standard 13A plug. These are usually two-zone domino hobs, some 60cm models with power-sharing between zones, and a handful of full-size hobs with a "plug and play" or "13A" label. If your kitchen has no cooker circuit, these exist specifically for you.
The practical first step costs nothing: look behind your current hob. If there's already a cooker circuit serving an electric hob, you almost certainly have what you need.
What Actually Matters
Induction hobs draw a lot of current because they convert electricity into heat at close to 90 per cent efficiency and they do it fast. A typical four-zone hob has zones rated at 1.4kW, 1.8kW, 2.3kW and 3.7kW on boost, and if you could run all four flat out simultaneously you'd be drawing around 9kW — about 39A.
In practice you can't, and that's the key to the whole thing. Almost every induction hob has internal power management that caps total draw. Run two zones on boost and the others automatically reduce. Manufacturers publish this as a "total connected load" figure, which is the number that matters for wiring, and it's usually well below the sum of the individual zones.
Electricians then apply diversity — a standard calculation recognising that nobody runs every zone at maximum simultaneously for sustained periods. The conventional domestic calculation takes the first 10A of the load in full, then 30 per cent of the remainder. That's why a 7.4kW (32A) hob is comfortably fed by a 32A circuit rather than needing something enormous.
None of that changes the requirement for the circuit itself. Diversity affects the sizing calculation, not whether a dedicated circuit is needed.
Detailed Analysis
Working out what you already have
Three scenarios cover almost every UK kitchen.
You currently have an electric hob or an electric cooker. There's a cooker circuit. Look for a large switch on the wall, usually 45A, sometimes with a neon light, above or beside the worktop. Behind the hob or in the cupboard below there'll be a cooker connection unit — a flat plate with a cable outlet. This is what you need, and swapping a ceramic hob for induction is usually straightforward.
You currently have a gas hob. Probably no cooker circuit, only a 3A fused spur for the ignition. This is the case where costs appear, because running a new circuit from the consumer unit to the kitchen means lifting floors or chasing walls.
You have a freestanding cooker on a plug. Some smaller freestanding cookers do run from 13A. If so, that socket won't support a full-size induction hob and you're in the same position as the gas scenario.
One caution on scenario one: an existing cooker circuit isn't automatically adequate. Older installations sometimes used 4mm² cable on a 30A rewireable fuse, which may not suit a modern 7.4kW hob. An electrician will check cable size, breaker rating and RCD protection before confirming.
Reading the specification before you buy
Look for "total connected load" or "maximum power" in the technical specification rather than adding up the zone ratings.
| Total load | Current | What it needs |
|---|---|---|
| Up to 3.0kW | 13A | Standard 13A plug or fused spur |
| 3.0-3.6kW | 13-16A | 16A supply or a dedicated spur — check the manual |
| 3.6-7.4kW | 16-32A | Dedicated 32A cooker circuit, 6mm² cable |
| Over 7.4kW | 32A+ | 32A or 40A circuit; some need dual connection |
Where people get caught out is buying online, seeing "suitable for 13A" in a marketplace listing, and finding the manual says otherwise. Download the installation manual from the manufacturer's site before ordering. It's always available and it's definitive in a way retail listings aren't.
Where Part P sits
In England and Wales, installing a new circuit in a kitchen is notifiable work under Part P of the Building Regulations. That means it must be done either by an electrician registered with a competent person scheme, who self-certifies, or by anyone with prior notification to building control and an inspection.
Replacing an existing hob on an existing circuit is generally not notifiable — it's classed as replacement rather than new work. So swapping ceramic for induction where the circuit is already right is a much smaller regulatory matter than adding a circuit where none exists.
Scotland and Northern Ireland have separate frameworks with broadly similar effect. Whatever the letter of the rules, you want the certificate — selling the house, making an insurance claim, or getting a later electrician to work on the installation all go more smoothly with paperwork.
What it costs
Straightforward like-for-like replacement on an existing cooker circuit: £80-£150 for an electrician to disconnect the old hob and connect the new one, often an hour's work.
New circuit from the consumer unit: £250-£500 typically, driven almost entirely by cable route rather than the electrical work. A kitchen next to the consumer unit with an accessible route is the cheap end. A first-floor flat with a solid floor and no obvious route is the expensive end, and can go beyond it.
Consumer unit with no spare way: add £100-£200, or more if the board itself needs replacing — which older installations sometimes do.
Real-World Considerations
The plug-in induction hob category is genuinely useful and under-publicised. A 13A induction hob at around 2.9kW gives you two or three zones with power sharing — you can't run everything at full simultaneously, so boiling a large pan while frying means the frying zone steps down. For a household of one or two, or a flat with a gas supply being removed, that's an entirely workable compromise, and it avoids a £400 electrical job.
For anyone converting from gas as part of a wider kitchen refit, do the electrical work while the floor is up and the walls are open. Retrofitting a cooker circuit into a finished kitchen is the expensive version of the same job, and the difference is largely making good rather than electrical labour.
Worth flagging on running costs, since it's the usual reason for switching: induction is roughly 85-90 per cent efficient against about 70 per cent for ceramic and 40-55 per cent for gas. In practice a typical household saves perhaps £15-£30 a year switching from ceramic to induction. The real benefits are speed and control rather than the bill, and anyone told otherwise at the point of sale is being oversold.
One detail that catches people: induction electronics sit below the glass and need ventilation clearance, so you often can't fit one directly above a built-under oven without checking. Some combinations aren't permitted at all.
Common Mistakes Buyers Make
Adding up zone ratings instead of reading total connected load. The zones sum to more than the hob can actually draw, because of internal power management.
Trusting a marketplace listing over the manual. "13A" in a product description is not the same as the manufacturer's installation instruction.
Assuming an existing cooker circuit is automatically suitable. Older cable sizes and fuse types may not meet a modern hob's requirement.
Buying the hob before checking the kitchen. Look behind the current one first. Five minutes there can save a £400 surprise.
Fitting it yourself on an existing circuit to save money. Even where the work isn't notifiable, a hob connection done badly is a fire risk, and it will affect an insurance claim.
Alternatives Worth Considering
If no cooker circuit exists and running one is disproportionate, a 13A plug-in induction hob is the obvious route. Two or three zones with power sharing suits most small households, and the installation is genuinely just a socket.
Domino hobs — narrow two-zone units, typically 30cm wide — are another option. Two dominos side by side give four zones, and each may be individually plug-rated, spreading the load across two circuits. It's a more expensive way to buy four zones but it can avoid an electrical job entirely.
Where gas is staying and the motivation is control rather than fuel switching, a modern gas hob with a wok burner and cast iron supports is worth considering before committing to the electrical work. The efficiency argument for induction is real, but so is the £400 that never appears on the energy bill.
Frequently Asked Questions
Can an induction hob be plugged into a normal socket?
Some can. Models rated at or below about 3kW total are designed for a 13A supply. Full-size four-zone hobs at 6-7.4kW cannot and need a dedicated cooker circuit.
What amp circuit does an induction hob need?
Typically 32A on 6mm² cable for a standard full-size hob. Larger or higher-rated models may need 40A or a dual connection. The manual states the requirement.
Do I need a new circuit if I currently have a gas hob?
Almost certainly, unless you choose a 13A plug-in model. A gas hob usually has only a small fused spur for ignition.
Is fitting an induction hob notifiable under Part P?
Installing a new circuit in a kitchen is notifiable in England and Wales. Replacing a hob on an existing suitable circuit generally isn't, though it should still be done competently.
Why does the manual list a higher wattage than the circuit needs?
Because of diversity — the standard calculation recognising that all zones are never at maximum simultaneously. Electricians apply it when sizing the circuit.
Final Thoughts
Look behind your current hob before you look at hobs. An existing electric cooker circuit means this is a small job; a gas hob and no cooker circuit means either a few hundred pounds of electrical work or a plug-in model.
Read the manufacturer's installation manual rather than the retail listing, check the total connected load rather than adding up zones, and get the certificate. The hob is the easy part of this decision — the wiring behind it is what decides the cost.